Bare Copper Cable Meter by Meter

Products

12 AWG

Nexans ref. 10014248

  • Packaging: Reel
  • Conductor cross-section: 3.31 mm²
  • Approximate weight: 30 kg/km
  • Nominal outer diameter: 2.33 mm
  • Max. DC resistance of the conductor at 20°C: 5.457 Ohm/km
  • Ampacity: 51.0 A

 

10 AWG

Nexans ref. 10046916

  • Packaging: Reel
  • Conductor cross-section: 5.26 mm²
  • Approximate weight: 45.68 kg/km
  • Nominal outer diameter: 2.94 mm
  • Max. DC resistance of the conductor at 20°C: 3.417 Ohm/km
  • Ampacity: 68.0 A

 

8 AWG

Nexans ref. 10046918

  • Packaging: Reel
  • Conductor cross-section: 8.37 mm²
  • Approximate weight: 73.11 kg/km
  • Nominal outer diameter: 3.7 mm
  • Max. DC resistance of the conductor at 20°C: 2.142 Ohm/km
  • Ampacity: 98.0 A

 

6 AWG

Nexans ref. 10046919

  • Packaging: Reel
  • Conductor cross-section: 13.3 mm²
  • Approximate weight: 120.39 kg/km
  • Nominal outer diameter: 4.67 mm
  • Max. DC resistance of the conductor at 20°C: 1.346 Ohm/km
  • Ampacity: 124.0 A

 

2 AWG

Nexans ref. 10031217

  • Packaging: Reel
  • Conductor cross-section: 33.63 mm²
  • Approximate weight: 305 kg/km
  • Nominal outer diameter: 7.42 mm
  • Max. DC resistance of the conductor at 20°C: 0.532 Ohm/km
  • Ampacity: 209.0 A

 

3/0 AWG

Nexans ref. 10011317

  • Packaging: Drum (m)
  • Conductor cross-section: 85.03 mm²
  • Approximate weight: 771 kg/km
  • Nominal outer diameter: 11.94 mm
  • Max. DC resistance of the conductor at 20°C: 0.2111 Ohm/km
  • Ampacity: 382.0 A

 

4/0 AWG

Nexans ref. 10011316

  • Packaging: Drum (m)
  • Conductor cross-section: 107.22 mm²
  • Approximate weight: 943 kg/km
  • Nominal outer diameter: 13.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.167 Ohm/km
  • Ampacity: 66.0 A

 

250 Kcmil

Nexans ref. 10011315

  • Packaging: Reel
  • Conductor cross-section: 126.7 mm²
  • Approximate weight: 1149 kg/km
  • Nominal outer diameter: 14.62 mm
  • Max. DC resistance of the conductor at 20°C: 0.142 Ohm/km
  • Ampacity: 494.0 A

 

300 Kcmil

Nexans ref. 10012018

  • Packaging: Reel
  • Conductor cross-section: 152 mm²
  • Approximate weight: 1378 kg/km
  • Nominal outer diameter: 16.01 mm
  • Max. DC resistance of the conductor at 20°C: 0.118 Ohm/km
  • Ampacity: 556.0 A

 

350 Kcmil

Nexans ref. 10012794

  • Packaging: Reel
  • Conductor cross-section: 177.3 mm²
  • Approximate weight: 1608 kg/km
  • Nominal outer diameter: 17.29 mm
  • Max. DC resistance of the conductor at 20°C: 0.1011 Ohm/km
  • Ampacity: 610.0 A

 

400 Kcmil

Nexans ref. 10012772

  • Packaging: Reel
  • Conductor cross-section: 202.7 mm²
  • Approximate weight: 1838 kg/km
  • Nominal outer diameter: 18.49 mm
  • Max. DC resistance of the conductor at 20°C: 0.088 Ohm/km
  • Ampacity: 663.0 A

 

500 Kcmil

Nexans ref. 10027929

  • Packaging: Drum (m)
  • Conductor cross-section: 253.4 mm²
  • Approximate weight: 2295 kg/km
  • Nominal outer diameter: 29.67 mm
  • Max. DC resistance of the conductor at 20°C: 0.071 Ohm/km
  • Ampacity: 773.0 A

 

750 Kcmil

Nexans ref. 10012793

  • Packaging: Reel
  • Conductor cross-section: 380 mm²
  • Approximate weight: 3446 kg/km
  • Nominal outer diameter: 25.35 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Ampacity: 1000.0 A

 

1000 Kcmil

Nexans ref. 10012795

  • Packaging: Reel
  • Conductor cross-section: 506.7 mm²
  • Approximate weight: 4595 kg/km
  • Nominal outer diameter: 29.28 mm
  • Max. DC resistance of the conductor at 20°C: 0.035 Ohm/km
  • Ampacity: 1193.0 A

 

Description

Description

Standards

  • Product
    ASTM B 3; ASTM B 496; ASTM B 8
  • National
    NTC 307; NTC 359

Benefits

Innovative product that provides more security and confidence to our clients.

• Inventory meter control
• Product installation without delays.
• Guarantee of cable quality and authenticity.
• Prevention of losses due to theft.
• Guarantee of exact length cutting.
• Easy and quick gauge identification.

Applications

Transmission and distribution of electrical energy, in aerial installation and for grounding systems. Bare Copper Cable Meter by Meter - Marking on bare copper, Meter by Meter, to achieve a higher level of precision when cutting.

Construction

Conductor

Soft bare copper conductor, concentric stranded.

Applicable Standards.

ASTM B1, NTC 1744, ASTM B2, NTC 1745, ASTM B3, NTC 359, ASTM B8, NTC 307, ASTM B496, IEC 60228

Certificate

RETIE No.00814
RETIE No.08189
RETIE No.00410
RETIE No.07517
RETIE No.07785
RETIE No.07925

Ampacity Conditions

  • Current capacity for ambient temperature of 40°C and conductor temperature of 80°C. Wind speed 610mm/s, According to NTC 2050, Table 310.15(B)(21).

NOTE:

The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.

Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantities.

Marking on bare copper, Meter by Meter, to achieve a higher level precision when cutting.
Discover more: https://www.nexans.co/en/services/Metro-a-Metro.html.

Innovation Available - METER By METER

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Conductor flexibility
Class B

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close