FREETOX Medium Voltage, multi-core XLPE/LFH

Products

FREETOX 3x2+3x8 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 33.6 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 140 A
  • Permissible current rating buried 20°C: 180 A
  • Perm. Current in duct 20°C: 135 A

 

FREETOX 3x1+3x8 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 1
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 42.4 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 160 A
  • Permissible current rating buried 20°C: 200 A
  • Perm. Current in duct 20°C: 155 A

 

FREETOX 3x1/0+3x6 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 1/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 53.5 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 185 A
  • Permissible current rating buried 20°C: 230 A
  • Perm. Current in duct 20°C: 175 A

 

FREETOX 3x2/0+3x8 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.4 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 215 A
  • Permissible current rating buried 20°C: 260 A
  • Perm. Current in duct 20°C: 200 A

 

FREETOX 3x3/0+3x4 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 3/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 85 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 250 A
  • Permissible current rating buried 20°C: 295 A
  • Perm. Current in duct 20°C: 230 A

 

FREETOX 3x4/0 AWG 8kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 4/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 107 mm²
  • Operating voltage: 8 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 325 A
  • Permissible current rating buried 20°C: 350 A
  • Perm. Current in duct 20°C: 285 A

 

FREETOX 3x2AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 33.6 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 140 A
  • Permissible current rating buried 20°C: 180 A
  • Perm. Current in duct 20°C: 135 A

 

FREETOX 3x2/0AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.4 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 215 A
  • Permissible current rating buried 20°C: 260 A
  • Perm. Current in duct 20°C: 200 A

 

FREETOX 3x4/0 AWG 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 4/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 107 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 285 A
  • Permissible current rating buried 20°C: 335 A
  • Perm. Current in duct 20°C: 265 A

 

FREETOX-MZG 35kV 133%IL 3X2/0+3X4AWG CMPCT (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10048665

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 245 A
  • Permissible current rating buried 20°C: 270 A
  • Perm. Current in duct 20°C: 220 A

 

FREETOX-G 5kV 3X2/0+1X2AWG (Cta AZ-NE-RJ) AMARILLO.

Nexans ref. 10048254

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.4 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 215 A
  • Permissible current rating buried 20°C: 260 A
  • Perm. Current in duct 20°C: 200 A

 

FREETOX-MZG 8kV 3X2/0+3X6AWG (Cta AZ-NE-RJ) ROJO.

Nexans ref. 10047753

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 8 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 245 A
  • Permissible current rating buried 20°C: 270 A
  • Perm. Current in duct 20°C: 220 A

 

FREETOX-MZG 25kV 133%IL 3X2/0+3X6AWG (Cta AZ-NE-RJ) ROJO.

Nexans ref. 10047754

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 25 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 245 A
  • Permissible current rating buried 20°C: 270 A
  • Perm. Current in duct 20°C: 220 A

 

FREETOX-MAZ 5kV 3X2/0AWG (Cta AZ-NE-RJ) AMARILLO.

Nexans ref. 10049194

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 215 A
  • Permissible current rating buried 20°C: 260 A
  • Perm. Current in duct 20°C: 200 A

 

FREETOX-MAZG 35kV 133%IL 3X2/0+3X4AWG CMPCT (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10048664

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 245 A
  • Permissible current rating buried 20°C: 270 A
  • Perm. Current in duct 20°C: 220 A

 

FREETOX-MAZG 15kV 3X2/0+3X6AWG (Cta AZ-NE-RJ) AMARILLO.

Nexans ref. 10048178

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: - kcmil
  • Conductor cross-section: 67.42 mm²
  • Operating voltage: 15 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 245 A
  • Permissible current rating buried 20°C: 270 A
  • Perm. Current in duct 20°C: 220 A

 

FREETOX-MAG 15kV 3X350+3X4AWG(AZ-NE-RJ) ROJO(326).

Nexans ref. 10049651

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 350 kcmil
  • Conductor cross-section: 177.4 mm²
  • Operating voltage: 15 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 435 A
  • Permissible current rating buried 20°C: 460 A
  • Perm. Current in duct 20°C: 375 A

 

FREETOX-MAZG 8kV 133%IL 3X350+3X1AWG CMPCT (Cta AZ-NE-RJ) NARANJA.

Nexans ref. 10048638

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 350 kcmil
  • Conductor cross-section: 177.4 mm²
  • Operating voltage: 8 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 435 A
  • Permissible current rating buried 20°C: 460 A
  • Perm. Current in duct 20°C: 375 A

 

FREETOX 3x500+1x250 kcmil 5kV 133%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): -
  • Conductor cross-section: 500 kcmil
  • Conductor cross-section: 253 mm²
  • Operating voltage: 5 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 485 A
  • Permissible current rating buried 20°C: 530 A
  • Perm. Current in duct 20°C: 430 A

 

FREETOX-MZG 35kV 133%IL 3X500+3X3/0AWG CMPCT (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10048641

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 500 kcmil
  • Conductor cross-section: 253 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 535 A
  • Permissible current rating buried 20°C: 550 A
  • Perm. Current in duct 20°C: 450 A

 

FREETOX-MZG 35kV 3X500kcmil+3X1AWG CLB (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10047767

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 500 kcmil
  • Conductor cross-section: 253 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 535 A
  • Permissible current rating buried 20°C: 550 A
  • Perm. Current in duct 20°C: 450 A

 

FREETOX-G 35kV 133%IL 3X500+3X3/0AWG CMPCT (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10048640

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 500 kcmil
  • Conductor cross-section: 253 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 535 A
  • Permissible current rating buried 20°C: 550 A
  • Perm. Current in duct 20°C: 450 A

 

FREETOX-MAZG 35kV 133%IL 3X500+3X3/0AWG CMPCT (Cta AZ-NE-RJ) GRIS.

Nexans ref. 10048663

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL):
  • Conductor cross-section: 500 kcmil
  • Conductor cross-section: 253 mm²
  • Operating voltage: 35 kV
  • Insulation Level: 133 %
  • Perm current rating in air 40°C: 535 A
  • Permissible current rating buried 20°C: 550 A
  • Perm. Current in duct 20°C: 450 A

 

FREETOX 3x750 kcmil 25kV 100%IL

Nexans ref.

  • Packaging: Cut to length (300m)
  • Conductor cross-section (AWG/KCMIL): -
  • Conductor cross-section: 750 kcmil
  • Conductor cross-section: 380 mm²
  • Operating voltage: 25 kV
  • Insulation Level: 100 %
  • Perm current rating in air 40°C: 670 A
  • Permissible current rating buried 20°C: 665 A
  • Perm. Current in duct 20°C: 545 A

 

Description

Description

Standards

  • Product
    ASTM B 3; ASTM B 496; ASTM B 8; ICEA S-93-639; IEC 60228; IEC 60502-2
  • Test
    IEC 60332-1-2; IEC 60332-3-24 Cat.C; IEC 60754-1; IEC 60754-2; IEC 61034-2
  • International
    NES 713

Applications

Power shielded cable for fixed installations, used for connection of transformers, switchgears, GIS substations, motors, generators, feeders in distribution networks. Suitable to be installed directly buried, buried in ducts, in conduits, cable trays or in free air.

Construction: Multi-core cable.

Conductor: Compact-round stranded copper conductor. For AWG and kcmil sizes: class B according to ASTM B-3, ASTM B8 and ASTM B-496 according to requirements of ICEA S-93-639. For standard mm² sizes: class 2 according to IEC 60228.

Conductor shield: Extruded semiconducting material.

Insulation: Tree-Retardant crosslinked polyethylene (TR-XLPE)  or crosslinked polyethylene (XLPE) with excellent electrical properties, good resistance to ozone and chemical agents.

Insulation shield: Extruded semiconducting material.

Metallic shield: Copper tape applied helically in intimate contact with the underlaying semiconducting layer, 12% nominal overlap.

Ground conductor (Optional): One or three flexible bare copper conductors, class 5 according to IEC 60228, in contact with the metallic shields.

Oversheath: Low fire hazard polyolefin (LFH), flame and fire retardant, low smoke emission, resistant to weather and UV radiation. Color upon request.

Marking: NEXANS CHILE FREETOX "size" "Rated voltage" Cu XLPE "Nominal Insulation Thickness" (1) 90°C  "Manuf. order" "Date"

(1) Nominal Insulation Thickness information on marking only applies for cables according to ICEA S-93-639.

 

Design Alternatives

FREETOX-RAT: Resistant to rodent attack.

FREETOX-MAG: Armored cable with galvanized steel wires.

FREETOX-MZG: Armored cable with two flat galvanized steel tapes.

FREETOX-MAZG: Armored cable with galvanized steel wires and two flat galvanized steel  tapes.

INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV MULTI-CORE CABLES

(1) Current carrying capacities based on NEC/NFPA 70 for installations were ducts and cables are not directly exposed to solar radiation.

De-rating factors must be applied according to specific instalation conditions.

INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV MULTI-CORE CABLES

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Outer sheath
Low fire hazard Polyolefin
Halogen free
IEC 60754-1
Lead free
Yes

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1-2
Fire retardant
IEC 60332-3-24 (cat C)
Smoke density
IEC 61034-2
Oil resistance
ICEA S-93-639 (70°C/4h)
U.V resistance
UL 1581

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close