ET - Medium voltage, single core cable, EPR/PVC
ET - Medium voltage, single core cable, EPR/PVC
Power cable for fixed installations in medium voltage systems.
EPR/PVC. 90°C. 5-8-15-25-35-46 kV according to ICEA S-96-639. 3,6/6 - 6/10 - 8,7/15 - 12/20 - 18/30 kV according to IEC 60502-2. Read moreET 4 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 17.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 35 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET 50 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 2/0 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 322 A
ET 4/0 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 120 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 417 A
ET 185 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 240 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 544 A
ET 300 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 911 A
ET 4 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 17.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 25 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 17.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET 2 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 35 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET 1 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 1/0 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 2/0 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 322 A
ET 4/0 AWG 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 120 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 417 A
ET 185 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 240 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 544 A
ET 300 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 911 A
ET 4 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 25 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET 2 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 35 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET 1 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 1/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 70 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET 120 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 240 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET 300 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET 4 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 25 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET 2 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 35 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET 1 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 1/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 2/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET 120 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 240 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET 300 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET 2 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET 35 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET 1 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 70 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET 120 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET 150 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET 185 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET 240 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET 300 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET 400 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET 500 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET 630 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET 35 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET 50 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 70 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET 4/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET 150 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET 185 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET 240 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET 300 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET 400 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET 500 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 47.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET 630 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET 1 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 2/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 3/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 150 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 49.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 52.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 1 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 2/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 3/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 150 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 49.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 52.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 55.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 50 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 70 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 95 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 150 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 45.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 47.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 53.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 57.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 50 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 70 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 3/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 150 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 51.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 54.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 57.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 60.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 120 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 423 A
- Permissible current rating buried 20°C: 428 A
- Perm. Current in duct 20°C: 374 A
ET 185 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 544 A
- Permissible current rating buried 20°C: 532 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 633 A
- Permissible current rating buried 20°C: 597 A
- Perm. Current in duct 20°C: 526 A
ET 300 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 52.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 716 A
- Permissible current rating buried 20°C: 650 A
- Perm. Current in duct 20°C: 570 A
ET 400 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 55.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 844 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 641 A
ET 500 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 58.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 964 A
- Permissible current rating buried 20°C: 836 A
- Perm. Current in duct 20°C: 734 A
ET 630 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 62.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1079 A
- Permissible current rating buried 20°C: 896 A
- Perm. Current in duct 20°C: 786 A
ET 4/0 AWG 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 397 A
- Permissible current rating buried 20°C: 400 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 51.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 423 A
- Permissible current rating buried 20°C: 428 A
- Perm. Current in duct 20°C: 374 A
ET 150 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 52.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 480 A
- Permissible current rating buried 20°C: 480 A
- Perm. Current in duct 20°C: 421 A
ET 185 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 54.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 544 A
- Permissible current rating buried 20°C: 532 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 56.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 633 A
- Permissible current rating buried 20°C: 597 A
- Perm. Current in duct 20°C: 526 A
ET 300 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 59.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 716 A
- Permissible current rating buried 20°C: 650 A
- Perm. Current in duct 20°C: 570 A
ET 400 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 62.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 844 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 641 A
ET 500 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 65.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 964 A
- Permissible current rating buried 20°C: 836 A
- Perm. Current in duct 20°C: 734 A
ET 630 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 68.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1079 A
- Permissible current rating buried 20°C: 896 A
- Perm. Current in duct 20°C: 786 A
ET 4 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 16.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 25 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 17.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET 2 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 35 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET 1 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 1/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 2/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 95 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 322 A
ET 120 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 417 A
ET 240 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 544 A
ET 300 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 911 A
ET 4 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET 25 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET 2 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 35 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET 1 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET 1/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 2/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET 4/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 120 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET 150 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 240 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET 300 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET 400 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET 500 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET 630 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 44.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET 25 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 176 A
- Perm. Current in duct 20°C: 150 A
ET 35 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET 1 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 2/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET 3/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET 4/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET 150 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET 300 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET 400 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET 500 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET 630 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET 1 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 1/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 2/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET 70 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 3/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 120 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 150 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 44.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 50 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET 2/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 265 A
ET 70 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET 3/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 95 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET 4/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 344 A
ET 150 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET 185 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET 240 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET 300 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET 400 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET 500 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 49.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET 630 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 53.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET 25 mm² 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 25 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 17.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET 2 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: 33.6 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 18.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET 2 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: 33.6 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET 2 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: 33.6 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 21.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET 35 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 35 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET 1 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: 42.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 19.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET 1 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: 42.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET 50 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 50 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET 1/0 AWG 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: 53.5 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 20.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET 2/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET 2/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET 2/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET 2/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 265 A
ET 2/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.4 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 265 A
ET 3/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: 85 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 302 A
ET 3/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: 85 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 22.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET 4/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 4/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 4/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET 4/0 AWG 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 397 A
- Permissible current rating buried 20°C: 400 A
- Perm. Current in duct 20°C: 344 A
ET 4/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 23.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET 120 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 120 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET 250 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 37.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 51.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 436 A
- Permissible current rating buried 20°C: 443 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 127 kcmil
- Conductor cross-section: 250 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 150 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 150 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 480 A
- Permissible current rating buried 20°C: 480 A
- Perm. Current in duct 20°C: 421 A
ET 350 kcmil 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 357 A
ET 350 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 177 kcmil
- Conductor cross-section: 350 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 457 A
ET 185 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 185 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 27.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET 185 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 185 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET 240 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class 2
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 240 kcmil
- Conductor cross-section: - mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET 250 kcmil 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 25.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 436 A
- Permissible current rating buried 20°C: 443 A
- Perm. Current in duct 20°C: 378 A
ET 250 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 24.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 26.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET 250 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 378 A
ET 500 kcmil 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 500 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 500 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 500 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 33.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 500 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 253 kcmil
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 350 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 29.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 32.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 357 A
ET 350 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 47.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 532 A
- Permissible current rating buried 20°C: 523 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 54.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 532 A
- Permissible current rating buried 20°C: 523 A
- Perm. Current in duct 20°C: 457 A
ET 350 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 28.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET 350 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Nominal outer diameter: 31.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET 750 kcmil 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 380 kcmil
- Conductor cross-section: 750 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 380 kcmil
- Conductor cross-section: 750 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 380 kcmil
- Conductor cross-section: 750 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 380 kcmil
- Conductor cross-section: 750 mm²
- Nominal outer diameter: 55.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 820 A
- Permissible current rating buried 20°C: 714 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 380 kcmil
- Conductor cross-section: 750 mm²
- Nominal outer diameter: 46.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 500 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 45.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 49.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 655 A
- Permissible current rating buried 20°C: 613 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 57.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 655 A
- Permissible current rating buried 20°C: 613 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 30.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET 500 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 34.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 500 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 25kV 133%IL 500kcmil CELESTE.
Nexans ref. 10048430
- Packaging: Cut to length (300m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): 500
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 557 A
ET 1000 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 507 kcmil
- Conductor cross-section: 1000 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 507 kcmil
- Conductor cross-section: 1000 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 507 kcmil
- Conductor cross-section: 1000 mm²
- Nominal outer diameter: 54.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 507 kcmil
- Conductor cross-section: 1000 mm²
- Nominal outer diameter: 65.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 972 A
- Permissible current rating buried 20°C: 843 A
- Perm. Current in duct 20°C: 807 A
ET 750 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 42.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 45.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 48.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 53.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 61.0 mm
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 820 A
- Permissible current rating buried 20°C: 714 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 35.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 36.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET 750 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 38.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET 750 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Nominal outer diameter: 41.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 695 A
ET 1000 kcmil 5kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 39.0 mm
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 45.0 mm
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 47.0 mm
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 49.0 mm
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 52.0 mm
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 57.0 mm
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 59.0 mm
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 972 A
- Permissible current rating buried 20°C: 843 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 40.0 mm
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET 1000 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 43.0 mm
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 45.0 mm
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
ET 1000 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor flexibility: Class B
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Nominal outer diameter: 50.0 mm
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 807 A
Description
Description
Standards
-
ProductASTM B 3; ASTM B 496; ASTM B 8; ICEA S-93-639; IEC 60228; IEC 60502-2
-
TestIEC 60332-1-2
Applications
Power shielded cable for fixed installations, used for connection of transformers, switchgears, GIS substations, motors, generators, feeders in distribution networks. Suitable to be installed directly buried, buried in ducts, in conduits or in free air.
Construction: Singlecore cable.
Conductor: Compact-round stranded copper conductor. For AWG and kcmil sizes: class B according to ASTM B-3, ASTM B8 and ASTM B-496 according to requirements of ICEA S-93-639. For standard mm² sizes: class 2 according to IEC 60228.
Conductor shield: Extruded semiconducting material.
Insulation: Ethylene propylene rubber (EPR) with excellent electrical properties, good resistance to ozone and chemical agents.
Insulation shield: Extruded semiconducting material.
Metallic shield: Copper tape applied helically in intimate contact with the underlaying semiconducting layer. 12% mimimum overlap.
Oversheath: Polyvinyl Chloride (PVC), flame retardant, resistant to weather and UV radiation. Color upon request.
Marking: NEXANS CHILE ET "size" "Rated voltage" Cu EPR "Nominal Insulation Thickness" (1) 90°C "Manuf. order" "Date"
(1) Nominal Insulation Thickness information on marking only applies for cables according to ICEA S-93-639.
Design Alternatives
ET-TC: Fire retardant according to IEC 60332-3-24 Cat. C.
ET-RAT: Resistant to rodent attack.
HFFR alternative:
FREETOX-E Medium Voltage
INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV CABLES
(1) Current carrying capacities based on ICEA P-46-426, for installations were ducts and cables are not directly exposed to solar radiation.
De-rating factors must be applied according to specific installation conditions.
INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV CABLES
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania