- Markets
- Catalog
- Services & Solutions
- Tools and Resources
- Downloads
- About Nexans
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- The path to effective fire safety in buildings
- Big data & AI
- Electrical and Fire Safety
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Search
- Contact us
- Compare
- Sign in
EPR - Medium Voltage, multi core, EPR/PVC-TC
EPR - Medium Voltage, multi core, EPR/PVC-TC
Power cable for fixed installations in medium voltage systems.
EPR/PVC. 90°C. 5-8-15-25-35-46 kV according to ICEA S-96-639. 3,6/6 - 6/10 - 8,7/15 - 12/20 - 18/30 kV according to IEC 60502-2. Read moreET-TC 630 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 630 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET-TC 185 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET-TC 150 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET-TC 120 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET-TC 4/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET-TC 95 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET-TC 2 AWG 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET-TC 630 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET-TC 500 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET-TC 400 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET-TC 300 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET-TC 240 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET-TC 185 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET-TC 150 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET-TC 4/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET-TC 95 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET-TC 50 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET-TC 1 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET-TC 2 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET-TC 25 mm² 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET-TC 4 AWG 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET-TC 630 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET-TC 500 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET-TC 400 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET-TC 300 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET-TC 240 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET-TC 185 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET-TC 150 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET-TC 4/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET-TC 95 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET-TC 50 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET-TC 1 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET-TC 2 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET-TC 25 mm² 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET-TC 4 AWG 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET-TC 630 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 1061 A
ET-TC 500 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 951 A
ET-TC 400 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 851 A
ET-TC 300 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 729 A
ET-TC 240 mm² 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 648 A
ET-TC 185 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 563 A
ET-TC 630 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET-TC 500 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET-TC 400 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET-TC 300 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 240 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET-TC 185 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET-TC 150 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET-TC 120 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET-TC 4/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET-TC 95 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET-TC 2 AWG 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET-TC 25 mm² 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 176 A
- Perm. Current in duct 20°C: 150 A
ET-TC 630 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 910 A
ET-TC 500 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 810 A
ET-TC 400 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 720 A
ET-TC 300 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 613 A
ET-TC 240 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 543 A
ET-TC 185 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 470 A
ET-TC 150 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 367 A
ET-TC 4/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 345 A
ET-TC 95 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 233 A
ET-TC 50 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 224 A
ET-TC 1 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 182 A
ET-TC 2 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 178 A
ET-TC 25 mm² 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 164 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 150 A
ET-TC 4 AWG 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 150 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 137 A
ET-TC 630 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 1061 A
ET-TC 500 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 951 A
ET-TC 400 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 851 A
ET-TC 300 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 729 A
ET-TC 240 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 648 A
ET-TC 185 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 563 A
ET-TC 150 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 493 A
ET-TC 120 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 430 A
ET-TC 4/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 400 A
ET-TC 95 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 370 A
ET-TC 3/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 345 A
ET-TC 70 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 307 A
ET-TC 2/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 300 A
ET-TC 1/0 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 260 A
ET-TC 50 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 249 A
ET-TC 1 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 225 A
ET-TC 35 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET-TC 630 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 630 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 630 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET-TC 500 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET-TC 400 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET-TC 300 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 240 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET-TC 185 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 563 A
- Permissible current rating buried 20°C: 545 A
- Perm. Current in duct 20°C: 467 A
ET-TC 150 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 484 A
- Perm. Current in duct 20°C: 414 A
ET-TC 120 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 429 A
- Perm. Current in duct 20°C: 366 A
ET-TC 4/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 403 A
- Perm. Current in duct 20°C: 344 A
ET-TC 95 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 376 A
- Perm. Current in duct 20°C: 321 A
ET-TC 3/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 354 A
- Perm. Current in duct 20°C: 302 A
ET-TC 70 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 318 A
- Perm. Current in duct 20°C: 270 A
ET-TC 2/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 312 A
- Perm. Current in duct 20°C: 265 A
ET-TC 1/0 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 1 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 240 A
- Perm. Current in duct 20°C: 204 A
ET-TC 35 mm² 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 200 A
- Permissible current rating buried 20°C: 215 A
- Perm. Current in duct 20°C: 183 A
ET-TC 2 AWG 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 210 A
- Perm. Current in duct 20°C: 179 A
ET-TC 630 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1206 A
- Permissible current rating buried 20°C: 1034 A
- Perm. Current in duct 20°C: 899 A
ET-TC 500 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1051 A
- Permissible current rating buried 20°C: 925 A
- Perm. Current in duct 20°C: 801 A
ET-TC 400 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 913 A
- Permissible current rating buried 20°C: 825 A
- Perm. Current in duct 20°C: 713 A
ET-TC 300 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 759 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 240 mm² 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 661 A
- Permissible current rating buried 20°C: 629 A
- Perm. Current in duct 20°C: 539 A
ET-TC 150 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 493 A
ET-TC 120 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 430 A
ET-TC 4/0 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 400 A
ET-TC 95 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 370 A
ET-TC 3/0 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 345 A
ET-TC 70 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 307 A
ET-TC 2/0 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 300 A
ET-TC 1/0 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 260 A
ET-TC 50 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 249 A
ET-TC 1 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 225 A
ET-TC 35 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET-TC 2 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 190 A
ET-TC 25 mm² 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET-TC 4 AWG 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 145 A
ET-TC 630 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1226 A
- Permissible current rating buried 20°C: 1061 A
- Perm. Current in duct 20°C: 1061 A
ET-TC 500 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1066 A
- Permissible current rating buried 20°C: 951 A
- Perm. Current in duct 20°C: 951 A
ET-TC 400 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 930 A
- Permissible current rating buried 20°C: 851 A
- Perm. Current in duct 20°C: 851 A
ET-TC 300 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 770 A
- Permissible current rating buried 20°C: 729 A
- Perm. Current in duct 20°C: 729 A
ET-TC 240 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 669 A
- Permissible current rating buried 20°C: 648 A
- Perm. Current in duct 20°C: 648 A
ET-TC 185 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 564 A
- Permissible current rating buried 20°C: 563 A
- Perm. Current in duct 20°C: 563 A
ET-TC 150 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 493 A
- Permissible current rating buried 20°C: 501 A
- Perm. Current in duct 20°C: 493 A
ET-TC 120 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 430 A
- Permissible current rating buried 20°C: 445 A
- Perm. Current in duct 20°C: 430 A
ET-TC 4/0 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 400 A
- Permissible current rating buried 20°C: 418 A
- Perm. Current in duct 20°C: 400 A
ET-TC 95 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 370 A
- Permissible current rating buried 20°C: 390 A
- Perm. Current in duct 20°C: 370 A
ET-TC 3/0 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 367 A
- Perm. Current in duct 20°C: 345 A
ET-TC 70 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 328 A
- Perm. Current in duct 20°C: 307 A
ET-TC 2/0 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 322 A
- Perm. Current in duct 20°C: 300 A
ET-TC 1/0 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 283 A
- Perm. Current in duct 20°C: 260 A
ET-TC 50 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 272 A
- Perm. Current in duct 20°C: 249 A
ET-TC 1 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Conductor cross-section: 42.4 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 225 A
- Permissible current rating buried 20°C: 248 A
- Perm. Current in duct 20°C: 225 A
ET-TC 35 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 35 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 195 A
- Permissible current rating buried 20°C: 223 A
- Perm. Current in duct 20°C: 195 A
ET-TC 2 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 190 A
ET-TC 25 mm² 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET-TC 4 AWG 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 145 A
ET-TC 2 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 190 A
- Permissible current rating buried 20°C: 219 A
- Perm. Current in duct 20°C: 190 A
ET-TC 25 mm² 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 25 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 159 A
- Permissible current rating buried 20°C: 184 A
- Perm. Current in duct 20°C: 159 A
ET-TC 4 AWG 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Conductor cross-section: 21.2 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 145 A
- Permissible current rating buried 20°C: 169 A
- Perm. Current in duct 20°C: 145 A
ET-TC 630 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1079 A
- Permissible current rating buried 20°C: 896 A
- Perm. Current in duct 20°C: 786 A
ET-TC 500 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 964 A
- Permissible current rating buried 20°C: 836 A
- Perm. Current in duct 20°C: 734 A
ET-TC 400 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 844 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 641 A
ET-TC 300 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 716 A
- Permissible current rating buried 20°C: 650 A
- Perm. Current in duct 20°C: 570 A
ET-TC 240 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 633 A
- Permissible current rating buried 20°C: 597 A
- Perm. Current in duct 20°C: 526 A
ET-TC 185 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 544 A
- Permissible current rating buried 20°C: 532 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 480 A
- Permissible current rating buried 20°C: 480 A
- Perm. Current in duct 20°C: 421 A
ET-TC 120 mm² 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 423 A
- Permissible current rating buried 20°C: 428 A
- Perm. Current in duct 20°C: 374 A
ET-TC 4/0 AWG 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 397 A
- Permissible current rating buried 20°C: 400 A
- Perm. Current in duct 20°C: 347 A
ET-TC 630 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1079 A
- Permissible current rating buried 20°C: 896 A
- Perm. Current in duct 20°C: 786 A
ET-TC 500 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 964 A
- Permissible current rating buried 20°C: 836 A
- Perm. Current in duct 20°C: 734 A
ET-TC 400 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 844 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 641 A
ET-TC 300 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 716 A
- Permissible current rating buried 20°C: 650 A
- Perm. Current in duct 20°C: 570 A
ET-TC 240 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 633 A
- Permissible current rating buried 20°C: 597 A
- Perm. Current in duct 20°C: 526 A
ET-TC 185 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 544 A
- Permissible current rating buried 20°C: 532 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 480 A
- Permissible current rating buried 20°C: 480 A
- Perm. Current in duct 20°C: 421 A
ET-TC 120 mm² 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 423 A
- Permissible current rating buried 20°C: 428 A
- Perm. Current in duct 20°C: 374 A
ET-TC 4/0 AWG 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 397 A
- Permissible current rating buried 20°C: 400 A
- Perm. Current in duct 20°C: 347 A
ET-TC 630 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
ET-TC 630 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1200m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 630 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1181 A
- Permissible current rating buried 20°C: 1024 A
- Perm. Current in duct 20°C: 890 A
ET-TC 500 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 500 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1031 A
- Permissible current rating buried 20°C: 913 A
- Perm. Current in duct 20°C: 791 A
ET-TC 400 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 400 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 897 A
- Permissible current rating buried 20°C: 815 A
- Perm. Current in duct 20°C: 704 A
ET-TC 300 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 300 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 750 A
- Permissible current rating buried 20°C: 701 A
- Perm. Current in duct 20°C: 603 A
ET-TC 240 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 240 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 656 A
- Permissible current rating buried 20°C: 626 A
- Perm. Current in duct 20°C: 538 A
ET-TC 185 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 185 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 558 A
- Permissible current rating buried 20°C: 546 A
- Perm. Current in duct 20°C: 468 A
ET-TC 150 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 150 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 488 A
- Permissible current rating buried 20°C: 487 A
- Perm. Current in duct 20°C: 416 A
ET-TC 120 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 120 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 425 A
- Permissible current rating buried 20°C: 432 A
- Perm. Current in duct 20°C: 369 A
ET-TC 4/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 107 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 395 A
- Permissible current rating buried 20°C: 406 A
- Perm. Current in duct 20°C: 347 A
ET-TC 95 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 95 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 367 A
- Permissible current rating buried 20°C: 379 A
- Perm. Current in duct 20°C: 323 A
ET-TC 3/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 85 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 345 A
- Permissible current rating buried 20°C: 357 A
- Perm. Current in duct 20°C: 304 A
ET-TC 70 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 70 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 307 A
- Permissible current rating buried 20°C: 319 A
- Perm. Current in duct 20°C: 271 A
ET-TC 2/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 67.4 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 300 A
- Permissible current rating buried 20°C: 313 A
- Perm. Current in duct 20°C: 266 A
ET-TC 1/0 AWG 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Conductor cross-section: 53.5 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 260 A
- Permissible current rating buried 20°C: 274 A
- Perm. Current in duct 20°C: 232 A
ET-TC 50 mm² 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Conductor cross-section: 50 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 249 A
- Permissible current rating buried 20°C: 263 A
- Perm. Current in duct 20°C: 223 A
EMT-TC 5kV 133%IL 3X2AWG (Cta AZ-NE-RJ) AMARILLO.
Nexans ref. 10050845
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Conductor cross-section: 33.6 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 161 A
- Permissible current rating buried 20°C: 189 A
- Perm. Current in duct 20°C: 149 A
ET-TC 250 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 250 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 250 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET-TC 250 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET-TC 250 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET-TC 250 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET-TC 250 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 379 A
ET-TC 250 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 445 A
ET-TC 250 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 250 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 250 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 442 A
- Perm. Current in duct 20°C: 378 A
ET-TC 250 kcmil 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 445 A
ET-TC 250 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 445 A
- Permissible current rating buried 20°C: 459 A
- Perm. Current in duct 20°C: 445 A
ET-TC 250 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 436 A
- Permissible current rating buried 20°C: 443 A
- Perm. Current in duct 20°C: 388 A
ET-TC 250 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 436 A
- Permissible current rating buried 20°C: 443 A
- Perm. Current in duct 20°C: 388 A
ET-TC 250 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 250 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Conductor cross-section: 127 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 440 A
- Permissible current rating buried 20°C: 446 A
- Perm. Current in duct 20°C: 380 A
ET-TC 300 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 488 A
- Perm. Current in duct 20°C: 417 A
ET-TC 300 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 488 A
- Perm. Current in duct 20°C: 417 A
ET-TC 300 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 497 A
ET-TC 300 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 488 A
- Perm. Current in duct 20°C: 417 A
ET-TC 300 kcmil 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 497 A
ET-TC 300 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 497 A
- Permissible current rating buried 20°C: 505 A
- Perm. Current in duct 20°C: 497 A
ET-TC 300 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 484 A
- Permissible current rating buried 20°C: 483 A
- Perm. Current in duct 20°C: 424 A
ET-TC 300 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 484 A
- Permissible current rating buried 20°C: 483 A
- Perm. Current in duct 20°C: 424 A
ET-TC 300 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 300 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 300 kcmil
- Conductor cross-section: 152 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 492 A
- Permissible current rating buried 20°C: 490 A
- Perm. Current in duct 20°C: 419 A
ET-TC 350 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 350 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 350 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET-TC 350 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET-TC 350 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET-TC 350 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET-TC 350 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 460 A
ET-TC 350 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 550 A
ET-TC 350 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 350 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 350 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 534 A
- Perm. Current in duct 20°C: 457 A
ET-TC 350 kcmil 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 550 A
ET-TC 350 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 550 A
- Permissible current rating buried 20°C: 551 A
- Perm. Current in duct 20°C: 550 A
ET-TC 350 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 532 A
- Permissible current rating buried 20°C: 523 A
- Perm. Current in duct 20°C: 460 A
ET-TC 350 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 532 A
- Permissible current rating buried 20°C: 523 A
- Perm. Current in duct 20°C: 460 A
ET-TC 350 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 350 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Conductor cross-section: 177 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 545 A
- Permissible current rating buried 20°C: 535 A
- Perm. Current in duct 20°C: 458 A
ET-TC 400 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 573 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 494 A
ET-TC 400 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 494 A
ET-TC 400 kcmil 5kV 133%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 599 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 591 A
ET-TC 400 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 573 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 494 A
ET-TC 400 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 599 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 591 A
ET-TC 400 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 595 A
- Permissible current rating buried 20°C: 573 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 599 A
- Permissible current rating buried 20°C: 591 A
- Perm. Current in duct 20°C: 591 A
ET-TC 400 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 573 A
- Permissible current rating buried 20°C: 553 A
- Perm. Current in duct 20°C: 487 A
ET-TC 400 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 573 A
- Permissible current rating buried 20°C: 553 A
- Perm. Current in duct 20°C: 487 A
ET-TC 400 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 400 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 400 kcmil
- Conductor cross-section: 203 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 590 A
- Permissible current rating buried 20°C: 572 A
- Perm. Current in duct 20°C: 491 A
ET-TC 500 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
ET-TC 500 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
EMT-TC-G 8kV 133%IL 3X500kcmil+3X1AWG (Cta AZ-NE-RJ) AMARILLO.
Nexans ref. 10048602
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL):
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 535 A
- Permissible current rating buried 20°C: 550 A
- Perm. Current in duct 20°C: 450 A
ET-TC 500 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET-TC 500 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 669 A
ET-TC 500 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET-TC 500 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 561 A
ET-TC 500 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 669 A
ET-TC 500 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
ET-TC 500 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
ET-TC 500 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET-TC 500 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 685 A
- Permissible current rating buried 20°C: 649 A
- Perm. Current in duct 20°C: 557 A
ET-TC 500 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 695 A
- Permissible current rating buried 20°C: 669 A
- Perm. Current in duct 20°C: 669 A
ET-TC 500 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 655 A
- Permissible current rating buried 20°C: 613 A
- Perm. Current in duct 20°C: 540 A
ET-TC 500 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 655 A
- Permissible current rating buried 20°C: 613 A
- Perm. Current in duct 20°C: 540 A
ET-TC 500 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
ET-TC 500 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Conductor cross-section: 253 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 680 A
- Permissible current rating buried 20°C: 646 A
- Perm. Current in duct 20°C: 555 A
ET-TC 600 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 600 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 600 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 617 A
ET-TC 600 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 617 A
ET-TC 600 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 777 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 734 A
ET-TC 600 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 711 A
- Perm. Current in duct 20°C: 612 A
ET-TC 600 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 617 A
ET-TC 600 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 777 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 734 A
ET-TC 600 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 600 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 600 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 711 A
- Perm. Current in duct 20°C: 612 A
ET-TC 600 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 765 A
- Permissible current rating buried 20°C: 711 A
- Perm. Current in duct 20°C: 612 A
ET-TC 600 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 777 A
- Permissible current rating buried 20°C: 734 A
- Perm. Current in duct 20°C: 734 A
ET-TC 600 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 721 A
- Permissible current rating buried 20°C: 653 A
- Perm. Current in duct 20°C: 573 A
ET-TC 600 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 721 A
- Permissible current rating buried 20°C: 653 A
- Perm. Current in duct 20°C: 573 A
ET-TC 600 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 600 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 600 kcmil
- Conductor cross-section: 304 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 756 A
- Permissible current rating buried 20°C: 706 A
- Perm. Current in duct 20°C: 608 A
ET-TC 25kV 133%IL 750kcmil ROJO.
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL):
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET-TC 750 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET-TC 750 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 831 A
ET-TC 750 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET-TC 750 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 702 A
ET-TC 750 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 831 A
ET-TC 750 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET-TC 750 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 885 A
- Permissible current rating buried 20°C: 805 A
- Perm. Current in duct 20°C: 695 A
ET-TC 750 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 900 A
- Permissible current rating buried 20°C: 831 A
- Perm. Current in duct 20°C: 831 A
ET-TC 750 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 820 A
- Permissible current rating buried 20°C: 714 A
- Perm. Current in duct 20°C: 623 A
ET-TC 750 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 820 A
- Permissible current rating buried 20°C: 714 A
- Perm. Current in duct 20°C: 623 A
ET-TC 750 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 750 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (2000m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 750 kcmil
- Conductor cross-section: 380 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 870 A
- Permissible current rating buried 20°C: 796 A
- Perm. Current in duct 20°C: 687 A
ET-TC 1000 kcmil 18/30 (36) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 30 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
ET-TC 1000 kcmil 12/20 (24) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 20 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
ET-TC 1000 kcmil 8kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 8 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET-TC 1000 kcmil 8kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 8 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET-TC 1000 kcmil 5kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 5 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 958 A
ET-TC 1000 kcmil 8,7/15 (17,5) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 15 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET-TC 1000 kcmil 6/10 (12) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 10 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 816 A
ET-TC 1000 kcmil 3,6/6 (7,2) kV
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 6 kV
- Insulation Level: - %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 958 A
ET-TC 1000 kcmil 25kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 25 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
ET-TC 1000 kcmil 25kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 25 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
ET-TC 1000 kcmil 15kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 15 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET-TC 1000 kcmil 15kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 15 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1060 A
- Permissible current rating buried 20°C: 932 A
- Perm. Current in duct 20°C: 807 A
ET-TC 1000 kcmil 5kV 100%IL
Nexans ref.
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 5 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1075 A
- Permissible current rating buried 20°C: 958 A
- Perm. Current in duct 20°C: 958 A
ET-TC 1000 kcmil 46kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 46 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 972 A
- Permissible current rating buried 20°C: 843 A
- Perm. Current in duct 20°C: 740 A
ET-TC 1000 kcmil 46kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 46 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 972 A
- Permissible current rating buried 20°C: 843 A
- Perm. Current in duct 20°C: 740 A
ET-TC 1000 kcmil 35kV 133%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 35 kV
- Insulation Level: 133 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
ET-TC 1000 kcmil 35kV 100%IL
Nexans ref.
- Packaging: Cut to length (1600m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 1000 kcmil
- Conductor cross-section: 507 mm²
- Operating voltage: 35 kV
- Insulation Level: 100 %
- Perm current rating in air 40°C: 1040 A
- Permissible current rating buried 20°C: 920 A
- Perm. Current in duct 20°C: 797 A
Description
Description
Standards
-
ProductASTM B 3; ASTM B 496; ASTM B 8; ICEA S-93-639; IEC 60228; IEC 60502-2
-
TestIEC 60332-1-2; IEC 60332-3-24 Cat.C
Applications
Power shielded cable for fixed installations, used for connection of transformers, switchgears, GIS substations, motors, generators, feeders in distribution networks. Suitable to be installed directly buried, buried in ducts, in conduits, in tray cables or in free air.
Construction: Multicore cable.
Conductor: Compact-round stranded copper conductor. For AWG and kcmil sizes: class B according to ASTM B-3, ASTM B8 and ASTM B-496 according to requirements of ICEA S-93-639. For standard mm² sizes: class 2 according to IEC 60228.
Conductor shield: Extruded semiconducting material.
Insulation: Ethylene propylene rubber (EPR) with excellent electrical properties, good resistance to ozone and chemical agents.
Insulation shield: Extruded semiconducting material.
Metallic shield: Copper tape applied helically in intimate contact with the underlaying semiconducting layer. 12% mimimum overlap.
Oversheath: Polyvinyl Chloride (PVC), flame retardant and fire retardant according to IEC 60332-3-24 Cat. C. Resistant to weather and UV radiation. Color upon request.
INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV MULTI-CORE CABLES
(1) Current carrying capacities based on NEC/NFPA 70 for installations were ducts and cables are not directly exposed to solar radiation.
De-rating factors must be applied according to specific instalation conditions.
INSTALLATION CONDITIONS FOR CURRENT CARRYING CAPACITIES_MV MULTI-CORE CABLES
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania