FREETOX-FLEX® Serie 3 (RZ1-K) mm²
FREETOX-FLEX® Serie 3 (RZ1-K) mm²
Flexible Fire Safety cable for fixed installation in low voltage systems.
XLPE/LFH(Low Fire Hazard). 90°C. 0,6/1kV (1,2 kV max). Chilean certificate as type RZ1-K according to SEC protocol PE N° 2/17. Read more1x1.5mm²
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 18 A
- Perm current rating in air 30°C: - A
1x10mm²
Nexans ref. 10012238
- Conductor cross-section: 10 mm²
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 66 A
- Perm current rating in air 30°C: 77 A
1x120mm²
Nexans ref. 10012247
- Conductor cross-section: 120 mm²
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 312 A
- Perm current rating in air 30°C: 400 A
1x150mm²
Nexans ref. 10012248
- Conductor cross-section: 150 mm²
- Permissible current rating buried 20°C: 431 A
- Permissible current rating buried/duct 20°C: 296 A
- Perm current rating in duct 30°C: 342 A
- Perm current rating in air 30°C: 464 A
1x16mm²
Nexans ref. 10012239
- Conductor cross-section: 16 mm²
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 88 A
- Perm current rating in air 30°C: 105 A
1x185mm²
Nexans ref. 10023292
- Conductor cross-section: 185 mm²
- Permissible current rating buried 20°C: 486 A
- Permissible current rating buried/duct 20°C: 332 A
- Perm current rating in duct 30°C: 384 A
- Perm current rating in air 30°C: 533 A
1x2.5mm²
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: - A
1x240mm²
Nexans ref. 10009598
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Permissible current rating buried 20°C: 563 A
- Permissible current rating buried/duct 20°C: 382 A
- Perm current rating in duct 30°C: 450 A
- Perm current rating in air 30°C: 634 A
1x25mm²
Nexans ref. 10012241
- Conductor cross-section: 25 mm²
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 117 A
- Perm current rating in air 30°C: 141 A
1x300mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Permissible current rating buried 20°C: 629 A
- Permissible current rating buried/duct 20°C: 431 A
- Perm current rating in duct 30°C: 514 A
- Perm current rating in air 30°C: 736 A
1x35mm²
Nexans ref. 10012243
- Conductor cross-section: 35 mm²
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 144 A
- Perm current rating in air 30°C: 176 A
1x4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 37 A
- Perm current rating in air 30°C: 42 A
1x50mm²
Nexans ref. 10012244
- Conductor cross-section: 50 mm²
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 175 A
- Perm current rating in air 30°C: 216 A
1x6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 48 A
- Perm current rating in air 30°C: 55 A
1x70mm²
Nexans ref. 10012245
- Conductor cross-section: 70 mm²
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 222 A
- Perm current rating in air 30°C: 279 A
1x95mm²
Nexans ref. 10012246
- Conductor cross-section: 95 mm²
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 269 A
- Perm current rating in air 30°C: 342 A
3X1.5mm²
Nexans ref. 10043853
- Packaging: Cut to length (m)
- Conductor cross-section: 1.5 mm²
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
3X10mm²
Nexans ref.
- Conductor cross-section: 10 mm²
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
3X120mm²
Nexans ref.
- Conductor cross-section: 120 mm²
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 268 A
- Perm current rating in air 30°C: 346 A
3X150mm²
Nexans ref.
- Conductor cross-section: 150 mm²
- Permissible current rating buried 20°C: 431 A
- Permissible current rating buried/duct 20°C: 296 A
- Perm current rating in duct 30°C: 300 A
- Perm current rating in air 30°C: 399 A
3X16mm²
Nexans ref.
- Conductor cross-section: 16 mm²
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
3X185mm²
Nexans ref.
- Conductor cross-section: 185 mm²
- Permissible current rating buried 20°C: 486 A
- Permissible current rating buried/duct 20°C: 332 A
- Perm current rating in duct 30°C: 340 A
- Perm current rating in air 30°C: 456 A
3X2.5mm²
Nexans ref. 10048200
- Packaging: Cut to length (m)
- Conductor cross-section: 2.5 mm²
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
3X240mm²
Nexans ref.
- Conductor cross-section: 240 mm²
- Permissible current rating buried 20°C: 563 A
- Permissible current rating buried/duct 20°C: 382 A
- Perm current rating in duct 30°C: 398 A
- Perm current rating in air 30°C: 538 A
3X25mm²
Nexans ref.
- Conductor cross-section: 25 mm²
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 127 A
3X35mm²
Nexans ref.
- Conductor cross-section: 35 mm²
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 128 A
- Perm current rating in air 30°C: 158 A
3X4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 35 A
- Perm current rating in air 30°C: 42 A
3X50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 154 A
- Perm current rating in air 30°C: 192 A
3X6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
3X70mm²
Nexans ref.
- Conductor cross-section: 70 mm²
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 194 A
- Perm current rating in air 30°C: 246 A
3X95mm²
Nexans ref.
- Conductor cross-section: 95 mm²
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 233 A
- Perm current rating in air 30°C: 298 A
4X1.5mm²
Nexans ref. 10040549
- Packaging: Cut to length (m)
- Conductor cross-section: 1.5 mm²
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
4X10mm²
Nexans ref.
- Conductor cross-section: 10 mm²
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
4X120mm²
Nexans ref.
- Conductor cross-section: 120 mm²
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 268 A
- Perm current rating in air 30°C: 346 A
4X16mm²
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 16 mm²
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
4X2.5mm²
Nexans ref. 10049387
- Packaging: Cut to length (m)
- Conductor cross-section: 2.5 mm²
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
4X25mm²
Nexans ref.
- Conductor cross-section: 25 mm²
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 127 A
4X35mm²
Nexans ref.
- Conductor cross-section: 35 mm²
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 128 A
- Perm current rating in air 30°C: 158 A
4X4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 35 A
- Perm current rating in air 30°C: 42 A
4X50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 154 A
- Perm current rating in air 30°C: 192 A
4X6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
4X70mm²
Nexans ref.
- Conductor cross-section: 70 mm²
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 194 A
- Perm current rating in air 30°C: 246 A
4X95mm²
Nexans ref.
- Conductor cross-section: 95 mm²
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 233 A
- Perm current rating in air 30°C: 298 A
5X1.5mm²
Nexans ref. 10040562
- Packaging: Cut to length (m)
- Conductor cross-section: 1.5 mm²
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
5X16mm²
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 16 mm²
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
5X2.5mm²
Nexans ref. 10040563
- Packaging: Cut to length (m)
- Conductor cross-section: 2.5 mm²
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
5X25mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 127 A
5X35mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 128 A
- Perm current rating in air 30°C: 158 A
5X50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 154 A
- Perm current rating in air 30°C: 192 A
5X70mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 194 A
- Perm current rating in air 30°C: 246 A
5x10mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
5x4mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 4 mm²
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 35 A
- Perm current rating in air 30°C: 42 A
5x6mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 6 mm²
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034-2
Applications
Flexible power and control cable for fixed installations. To be used in locations where concentration of people is high: hospitals, malls, offices, classrooms, auditoriums, etc.
It can be installed in free air, in ducts or cable trays. In small sizes, it is used as control cable for the inner part in cabinets.
Construction: Singlecore or multicore copper conductor from 3 to 5 cores.
Conductor: Class 5 flexible copper conductor according to IEC 60228.
Insulation: Crosslinked Polyethylene (XLPE) with excellent electrical properties, good resistance to ozone and chemical agents. Cores identification by colors.
Oversheath: Black FREETOX® compound. Low fire hazard thermoplastic, halogen free, low smoke emission, flame and fire retardant, resistant to weather and UV radiation. Other colors upon request.
Marking: Nexans FREETOX-FLEX SERIE 3 RZ1-K "size" 0.6/1 kV 90°C "Certificate number" "Manuf. order" "Date" CHILE "sequential length"
Design Alternatives
FREETOX-FLEX-RAT: Resistant to rodent attack.
FREETOX-FLEX-BLIND: Shielded with copper tape.
FREETOX-FLEX-BLIND-TZ: Shielded with a tinned copper braid.
Other sizes or construction different to those included in the catalog.
INSTALATION CONDITIONS FOR CURRENT CARRYING CAPACITIES
Current carrying capacities based on table N°4.4 according to RIC N°4, They are applied for installations where ducts and cables are not directly exposed to solar radiation.
(3) direct current buried at 20°C: Sheathed, single conductor or multi conductor cables (Three conductors with load) installed directly buried. Installation Method D2 according to RIC N°4.
(4) current in buried duct at 20°C: Single conductor or multi conductor cables (three conductors with load) installed in buried ducts. Installation Method D1 according to RIC N°4.
(5) duct current at 30°C: Up to three single conductors or multi conductor cables (three conductors with load) installed in ducts or trays attached to walls. Installation Method B1 and B2 according to RIC N°4.
(6) air current at 30°C: Multiconductor cables (Three conductors with load) installed freely in the air, in conductor ladders or in conductor baskets or in perforated trays. Installation Method E according to RIC N°4. Single conductor cables: Three conductors with load, in contact and in a flat arrangement, installed freely in the air, on conductor ladders or in conductor baskets or in perforated trays. Installation Method F according to RIC N°4.
For buried installations, a depth of 0,7 meters and a thermal resistivity of the soil of 1 K*m/W.
Current capacity correction factors must be considered according to the specific installation conditions.
INSTALATION CONDITIONS FOR CURRENT CARRYING CAPACITIES
NOTES
Values not defined as "maximum", "max.", "minimum" or "min." are not normative requirements in the standard and they are indicative only.
CERTIFICATE SEC RZ1-K (sections up to 35mm2 or 2AWG)
CERTIFICATE SEC RZ1-K (sections from 50mm2 to 1000mm2 or 1AWG to 1250kcmil)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania