THHN
THHN 0.6KV 14AWG
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 14
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 2.08 mm²
- Perm current rating in air 30°C: - A
- Perm current rating in duct 30°C: 21 A
THHN 0.6KV 12AWG
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 12
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 3.31 mm²
- Perm current rating in air 30°C: - A
- Perm current rating in duct 30°C: 28 A
THHN 0.6KV 10AWG
Nexans ref.
- Conductor cross-section (AWG/KCMIL): 10
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 5.26 mm²
- Perm current rating in air 30°C: 50 A
- Perm current rating in duct 30°C: 37 A
THHN 0.6KV 8AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 8
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 8.37 mm²
- Perm current rating in air 30°C: 68 A
- Perm current rating in duct 30°C: 49 A
THHN 0.6KV 6AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 13.3 mm²
- Perm current rating in air 30°C: 93 A
- Perm current rating in duct 30°C: 65 A
THHN 0.6KV 4AWG
Nexans ref.
- Packaging: Cut to length (1000m)
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 21.2 mm²
- Perm current rating in air 30°C: 126 A
- Perm current rating in duct 30°C: 86 A
THHN 0.6KV 2AWG
Nexans ref.
- Packaging: Cut to length (500m)
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 33.6 mm²
- Perm current rating in air 30°C: 172 A
- Perm current rating in duct 30°C: 114 A
THHN 0.6KV 1AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 42.4 mm²
- Perm current rating in air 30°C: 200 A
- Perm current rating in duct 30°C: 132 A
THHN 0.6KV 1/0AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 53.5 mm²
- Perm current rating in air 30°C: 234 A
- Perm current rating in duct 30°C: 152 A
THHN 0.6KV 2/0AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 67.4 mm²
- Perm current rating in air 30°C: 273 A
- Perm current rating in duct 30°C: 175 A
THHN 0.6KV 3/0AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 85 mm²
- Perm current rating in air 30°C: 318 A
- Perm current rating in duct 30°C: 201 A
THHN 0.6KV 4/0AWG
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Phase Conductor Cross Section: 107 mm²
- Perm current rating in air 30°C: 371 A
- Perm current rating in duct 30°C: 232 A
THHN 0.6KV 250kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 250 kcmil
- Phase Conductor Cross Section: 127 mm²
- Perm current rating in air 30°C: 415 A
- Perm current rating in duct 30°C: 257 A
THHN 0.6KV 350kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 350 kcmil
- Phase Conductor Cross Section: 177 mm²
- Perm current rating in air 30°C: 518 A
- Perm current rating in duct 30°C: 316 A
THHN 0.6KV 500kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: 500 kcmil
- Phase Conductor Cross Section: 253 mm²
- Perm current rating in air 30°C: 657 A
- Perm current rating in duct 30°C: 392 A
Description
Description
Standards
-
ProductUL 83
Use
residential and industrial low voltage installations, in enviroments without humidity. easy installation in ducts and trays thanks to its excellent qualities of glide.
Conductor
Annealed copper conductor, class B stranding.
Insulation
Polyvinyl chloride (PVC). Maximum conductor temperature 90°C. Available colors: white, red, black, blue and green.
Jacket
Nylon covering that allows easier pulling. Gasoline and oil resistant.
Marking
MADECO THHN - size- 600V 90°C GR II INGCER E-021-14-3148 NEXANS CHILE
CURRENT CARRYING CAPACITIES - THHN
Current carrying capacities based on table N°4.4 of RIC N°4.
Perm rating in duct at 30°C: Up to three single conductors with load installed in ducts embedded in walls, ambient temperature 30°C. Method A1 according to RIC N°4
Perm current rating in air at 30°C: Single conductor cables (Three conductors with load), in contact and a flat arrangement installed freely in the air, in conductor carrying ladders or in conductor carrying baskets or in perforated trays. Installation method F according to RIC N°4.
Current capacity correction factors must be considered according to the specific installation conditions.
CERTIFICATE SEC THHN
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Related products
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania