- Markets
- Catalog
- Services & Solutions
- Tools and Resources
- Downloads
- About Nexans
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- The path to effective fire safety in buildings
- Big data & AI
- Electrical and Fire Safety
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Search
- Contact us
- Compare
- Sign in
MULTI-FLEX® (RV-K)
MULTI-FLEX® (RV-K)
Flexible cable for fixed installation in low voltaje systems.
XLPE/PVC. 90°C. 0,6/1kV (1,2 kV max). Chilean certificate as type RV-K according to SEC protocol PE N° 2/15. Certification CIDET No. 06052 Read more1x14AWG
Nexans ref. 10003102
- Conductor cross-section: 2.08 mm²
- Conductor cross-section (AWG/KCMIL): 14
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 31 A
- Permissible current rating buried/duct 20°C: 30 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: - A
1x12AWG
Nexans ref. 10003129
- Conductor cross-section: 3.31 mm²
- Conductor cross-section (AWG/KCMIL): 12
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 39 A
- Permissible current rating buried/duct 20°C: 38 A
- Perm current rating in duct 30°C: 31 A
- Perm current rating in air 30°C: - A
1x8AWG
Nexans ref. 10003138
- Conductor cross-section: 8.37 mm²
- Conductor cross-section (AWG/KCMIL): 8
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 89 A
- Permissible current rating buried/duct 20°C: 63 A
- Perm current rating in duct 30°C: 59 A
- Perm current rating in air 30°C: 68 A
1x10AWG
Nexans ref. 10003134
- Conductor cross-section: 5.26 mm²
- Conductor cross-section (AWG/KCMIL): 10
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 69 A
- Permissible current rating buried/duct 20°C: 48 A
- Perm current rating in duct 30°C: 39 A
- Perm current rating in air 30°C: 50 A
1x6AWG
Nexans ref. 10003144
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 114 A
- Permissible current rating buried/duct 20°C: 80 A
- Perm current rating in duct 30°C: 79 A
- Perm current rating in air 30°C: 93 A
1x4AWG
Nexans ref. 10003153
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 147 A
- Permissible current rating buried/duct 20°C: 103 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 126 A
1x2AWG
Nexans ref. 10003157
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 189 A
- Permissible current rating buried/duct 20°C: 132 A
- Perm current rating in duct 30°C: 141 A
- Perm current rating in air 30°C: 172 A
1x1AWG
Nexans ref. 10003161
- Conductor cross-section: 42.4 mm²
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 216 A
- Permissible current rating buried/duct 20°C: 150 A
- Perm current rating in duct 30°C: 163 A
- Perm current rating in air 30°C: 200 A
1x1/0AWG
Nexans ref. 10003163
- Conductor cross-section: 53.5 mm²
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 245 A
- Permissible current rating buried/duct 20°C: 170 A
- Perm current rating in duct 30°C: 188 A
- Perm current rating in air 30°C: 234 A
1x2/0AWG
Nexans ref. 10003166
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 278 A
- Permissible current rating buried/duct 20°C: 192 A
- Perm current rating in duct 30°C: 217 A
- Perm current rating in air 30°C: 273 A
1x3/0AWG
Nexans ref. 10003167
- Conductor cross-section: 85 mm²
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 315 A
- Permissible current rating buried/duct 20°C: 218 A
- Perm current rating in duct 30°C: 251 A
- Perm current rating in air 30°C: 318 A
1x4/0AWG
Nexans ref. 10003170
- Conductor cross-section: 107 mm²
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 362 A
- Permissible current rating buried/duct 20°C: 248 A
- Perm current rating in duct 30°C: 290 A
- Perm current rating in air 30°C: 371 A
3X14AWG
Nexans ref. 10003109
- Conductor cross-section: 2.08 mm²
- Conductor cross-section (AWG/KCMIL): 14
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 31 A
- Permissible current rating buried/duct 20°C: 30 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 28 A
3X12AWG
Nexans ref. 10003128
- Conductor cross-section: 3.31 mm²
- Conductor cross-section (AWG/KCMIL): 12
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 39 A
- Permissible current rating buried/duct 20°C: 38 A
- Perm current rating in duct 30°C: 31 A
- Perm current rating in air 30°C: 38 A
3X10AWG
Nexans ref. 10003133
- Conductor cross-section: 5.26 mm²
- Conductor cross-section (AWG/KCMIL): 10
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 69 A
- Permissible current rating buried/duct 20°C: 48 A
- Perm current rating in duct 30°C: 38 A
- Perm current rating in air 30°C: 50 A
3X8AWG
Nexans ref. 10021291
- Conductor cross-section: 8.37 mm²
- Conductor cross-section (AWG/KCMIL): 8
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 89 A
- Permissible current rating buried/duct 20°C: 63 A
- Perm current rating in duct 30°C: 54 A
- Perm current rating in air 30°C: 67 A
3X6AWG
Nexans ref.
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 114 A
- Permissible current rating buried/duct 20°C: 80 A
- Perm current rating in duct 30°C: 72 A
- Perm current rating in air 30°C: 89 A
3X4AWG
Nexans ref.
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 147 A
- Permissible current rating buried/duct 20°C: 103 A
- Perm current rating in duct 30°C: 95 A
- Perm current rating in air 30°C: 114 A
3X2AWG
Nexans ref.
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 189 A
- Permissible current rating buried/duct 20°C: 132 A
- Perm current rating in duct 30°C: 125 A
- Perm current rating in air 30°C: 154 A
3X1AWG
Nexans ref.
- Conductor cross-section: 42.4 mm²
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 216 A
- Permissible current rating buried/duct 20°C: 150 A
- Perm current rating in duct 30°C: 144 A
- Perm current rating in air 30°C: 178 A
3X1/0AWG
Nexans ref.
- Conductor cross-section: 53.5 mm²
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 245 A
- Permissible current rating buried/duct 20°C: 170 A
- Perm current rating in duct 30°C: 165 A
- Perm current rating in air 30°C: 207 A
3X2/0AWG
Nexans ref.
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 278 A
- Permissible current rating buried/duct 20°C: 192 A
- Perm current rating in duct 30°C: 190 A
- Perm current rating in air 30°C: 240 A
3X3/0AWG
Nexans ref.
- Conductor cross-section: 85 mm²
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 315 A
- Permissible current rating buried/duct 20°C: 218 A
- Perm current rating in duct 30°C: 218 A
- Perm current rating in air 30°C: 278 A
3X4/0AWG
Nexans ref.
- Conductor cross-section: 107 mm²
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 362 A
- Permissible current rating buried/duct 20°C: 248 A
- Perm current rating in duct 30°C: 251 A
- Perm current rating in air 30°C: 322 A
4X10AWG
Nexans ref. 10017183
- Conductor cross-section: 5.26 mm²
- Conductor cross-section (AWG/KCMIL): 10
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 69 A
- Permissible current rating buried/duct 20°C: 48 A
- Perm current rating in duct 30°C: 38 A
- Perm current rating in air 30°C: 50 A
4X14AWG
Nexans ref. 10021255
- Conductor cross-section: 2.08 mm²
- Conductor cross-section (AWG/KCMIL): 14
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 31 A
- Permissible current rating buried/duct 20°C: 30 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 28 A
4X12AWG
Nexans ref. 10003125
- Conductor cross-section: 3.31 mm²
- Conductor cross-section (AWG/KCMIL): 12
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 39 A
- Permissible current rating buried/duct 20°C: 38 A
- Perm current rating in duct 30°C: 31 A
- Perm current rating in air 30°C: 38 A
4X8AWG
Nexans ref. 10014494
- Conductor cross-section: 8.37 mm²
- Conductor cross-section (AWG/KCMIL): 8
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 89 A
- Permissible current rating buried/duct 20°C: 63 A
- Perm current rating in duct 30°C: 54 A
- Perm current rating in air 30°C: 67 A
4X1AWG
Nexans ref.
- Conductor cross-section: 42.4 mm²
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 216 A
- Permissible current rating buried/duct 20°C: 150 A
- Perm current rating in duct 30°C: 144 A
- Perm current rating in air 30°C: 178 A
4X6AWG
Nexans ref. 10014495
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 114 A
- Permissible current rating buried/duct 20°C: 80 A
- Perm current rating in duct 30°C: 72 A
- Perm current rating in air 30°C: 89 A
4X4AWG
Nexans ref. 10003152
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 147 A
- Permissible current rating buried/duct 20°C: 103 A
- Perm current rating in duct 30°C: 95 A
- Perm current rating in air 30°C: 114 A
4X2AWG
Nexans ref. 10014496
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 189 A
- Permissible current rating buried/duct 20°C: 132 A
- Perm current rating in duct 30°C: 125 A
- Perm current rating in air 30°C: 154 A
4X1/0AWG
Nexans ref.
- Conductor cross-section: 53.5 mm²
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 245 A
- Permissible current rating buried/duct 20°C: 170 A
- Perm current rating in duct 30°C: 165 A
- Perm current rating in air 30°C: 207 A
4X2/0AWG
Nexans ref.
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 278 A
- Permissible current rating buried/duct 20°C: 192 A
- Perm current rating in duct 30°C: 190 A
- Perm current rating in air 30°C: 240 A
4X3/0AWG
Nexans ref.
- Conductor cross-section: 85 mm²
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 315 A
- Permissible current rating buried/duct 20°C: 218 A
- Perm current rating in duct 30°C: 218 A
- Perm current rating in air 30°C: 278 A
4X4/0AWG
Nexans ref.
- Conductor cross-section: 107 mm²
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 362 A
- Permissible current rating buried/duct 20°C: 248 A
- Perm current rating in duct 30°C: 251 A
- Perm current rating in air 30°C: 322 A
5X14AWG
Nexans ref. 10022092
- Conductor cross-section: 2.08 mm²
- Conductor cross-section (AWG/KCMIL): 14
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 31 A
- Permissible current rating buried/duct 20°C: 30 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 28 A
1x1.5mm²
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 18 A
- Perm current rating in air 30°C: - A
1x2.5mm²
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: - A
1x4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 37 A
- Perm current rating in air 30°C: 42 A
1x6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 48 A
- Perm current rating in air 30°C: 55 A
1x10mm²
Nexans ref.
- Conductor cross-section: 10 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 66 A
- Perm current rating in air 30°C: 77 A
1x50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 175 A
- Perm current rating in air 30°C: 216 A
1x16mm²
Nexans ref.
- Conductor cross-section: 16 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 88 A
- Perm current rating in air 30°C: 105 A
1x25mm²
Nexans ref.
- Conductor cross-section: 25 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 117 A
- Perm current rating in air 30°C: 141 A
1x35mm²
Nexans ref.
- Conductor cross-section: 35 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 144 A
- Perm current rating in air 30°C: 176 A
1x70mm²
Nexans ref.
- Conductor cross-section: 70 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 222 A
- Perm current rating in air 30°C: 279 A
1x95mm²
Nexans ref.
- Conductor cross-section: 95 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 269 A
- Perm current rating in air 30°C: 342 A
1x120mm²
Nexans ref.
- Conductor cross-section: 120 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 312 A
- Perm current rating in air 30°C: 400 A
1x150mm²
Nexans ref.
- Conductor cross-section: 150 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 431 A
- Permissible current rating buried/duct 20°C: 296 A
- Perm current rating in duct 30°C: 342 A
- Perm current rating in air 30°C: 464 A
1x185mm²
Nexans ref.
- Conductor cross-section: 185 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 486 A
- Permissible current rating buried/duct 20°C: 332 A
- Perm current rating in duct 30°C: 384 A
- Perm current rating in air 30°C: 533 A
3X2.5mm²
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
3X4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 35 A
- Perm current rating in air 30°C: 42 A
3X6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
3X10mm²
Nexans ref.
- Conductor cross-section: 10 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
3X25mm²
Nexans ref.
- Conductor cross-section: 25 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 127 A
3X35mm²
Nexans ref.
- Conductor cross-section: 35 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 128 A
- Perm current rating in air 30°C: 158 A
3X50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 154 A
- Perm current rating in air 30°C: 192 A
3X70mm²
Nexans ref.
- Conductor cross-section: 70 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 194 A
- Perm current rating in air 30°C: 246 A
3X95mm²
Nexans ref.
- Conductor cross-section: 95 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 233 A
- Perm current rating in air 30°C: 298 A
3X120mm²
Nexans ref.
- Conductor cross-section: 120 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 268 A
- Perm current rating in air 30°C: 346 A
3X150mm²
Nexans ref.
- Conductor cross-section: 150 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 431 A
- Permissible current rating buried/duct 20°C: 296 A
- Perm current rating in duct 30°C: 300 A
- Perm current rating in air 30°C: 399 A
3X185mm²
Nexans ref.
- Conductor cross-section: 185 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 486 A
- Permissible current rating buried/duct 20°C: 332 A
- Perm current rating in duct 30°C: 340 A
- Perm current rating in air 30°C: 456 A
4X6mm²
Nexans ref.
- Conductor cross-section: 6 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
1x240mm²
Nexans ref.
- Conductor cross-section: 240 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 563 A
- Permissible current rating buried/duct 20°C: 382 A
- Perm current rating in duct 30°C: 450 A
- Perm current rating in air 30°C: 634 A
3X1.5mm²
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
3X16mm²
Nexans ref.
- Conductor cross-section: 16 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
3X240mm²
Nexans ref.
- Conductor cross-section: 240 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 563 A
- Permissible current rating buried/duct 20°C: 382 A
- Perm current rating in duct 30°C: 398 A
- Perm current rating in air 30°C: 538 A
4X1.5mm²
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
4X2.5mm²
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
4X4mm²
Nexans ref.
- Conductor cross-section: 4 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 59 A
- Permissible current rating buried/duct 20°C: 42 A
- Perm current rating in duct 30°C: 35 A
- Perm current rating in air 30°C: 42 A
4X10mm²
Nexans ref.
- Conductor cross-section: 10 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
4X16mm²
Nexans ref.
- Conductor cross-section: 16 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
4X25mm²
Nexans ref.
- Conductor cross-section: 25 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 161 A
- Permissible current rating buried/duct 20°C: 113 A
- Perm current rating in duct 30°C: 105 A
- Perm current rating in air 30°C: 127 A
4X35mm²
Nexans ref.
- Conductor cross-section: 35 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 194 A
- Permissible current rating buried/duct 20°C: 136 A
- Perm current rating in duct 30°C: 128 A
- Perm current rating in air 30°C: 158 A
4X50mm²
Nexans ref.
- Conductor cross-section: 50 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 230 A
- Permissible current rating buried/duct 20°C: 159 A
- Perm current rating in duct 30°C: 154 A
- Perm current rating in air 30°C: 192 A
4X70mm²
Nexans ref.
- Conductor cross-section: 70 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 282 A
- Permissible current rating buried/duct 20°C: 197 A
- Perm current rating in duct 30°C: 194 A
- Perm current rating in air 30°C: 246 A
4X95mm²
Nexans ref.
- Conductor cross-section: 95 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 339 A
- Permissible current rating buried/duct 20°C: 232 A
- Perm current rating in duct 30°C: 233 A
- Perm current rating in air 30°C: 298 A
4X120mm²
Nexans ref.
- Conductor cross-section: 120 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 386 A
- Permissible current rating buried/duct 20°C: 263 A
- Perm current rating in duct 30°C: 268 A
- Perm current rating in air 30°C: 346 A
5X1.5mm²
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 23 A
- Permissible current rating buried/duct 20°C: 19 A
- Perm current rating in duct 30°C: 19 A
- Perm current rating in air 30°C: 19 A
5X2.5mm²
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 38 A
- Permissible current rating buried/duct 20°C: 33 A
- Perm current rating in duct 30°C: 24 A
- Perm current rating in air 30°C: 32 A
5x2/0AWG
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 67.4 mm²
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 278 A
- Permissible current rating buried/duct 20°C: 192 A
- Perm current rating in duct 30°C: 190 A
- Perm current rating in air 30°C: 240 A
5x1AWG
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 42.4 mm²
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 216 A
- Permissible current rating buried/duct 20°C: 150 A
- Perm current rating in duct 30°C: 144 A
- Perm current rating in air 30°C: 178 A
5X4AWG
Nexans ref. 10003150
- Packaging: Cut to length (m)
- Conductor cross-section: 21.2 mm²
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 147 A
- Permissible current rating buried/duct 20°C: 103 A
- Perm current rating in duct 30°C: 95 A
- Perm current rating in air 30°C: 114 A
4x150mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 431 A
- Permissible current rating buried/duct 20°C: 296 A
- Perm current rating in duct 30°C: 300 A
- Perm current rating in air 30°C: 399 A
1x300mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 629 A
- Permissible current rating buried/duct 20°C: 431 A
- Perm current rating in duct 30°C: 514 A
- Perm current rating in air 30°C: 736 A
4X185mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 486 A
- Permissible current rating buried/duct 20°C: 332 A
- Perm current rating in duct 30°C: 340 A
- Perm current rating in air 30°C: 456 A
5X6mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 6 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 74 A
- Permissible current rating buried/duct 20°C: 52 A
- Perm current rating in duct 30°C: 44 A
- Perm current rating in air 30°C: 54 A
5X10mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 98 A
- Permissible current rating buried/duct 20°C: 68 A
- Perm current rating in duct 30°C: 60 A
- Perm current rating in air 30°C: 75 A
5X16mm²
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Conductor cross-section (AWG/KCMIL): -
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 126 A
- Permissible current rating buried/duct 20°C: 89 A
- Perm current rating in duct 30°C: 80 A
- Perm current rating in air 30°C: 100 A
5X6AWG
Nexans ref. 10003145
- Packaging: Cut to length (m)
- Conductor cross-section: 13.3 mm²
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 114 A
- Permissible current rating buried/duct 20°C: 80 A
- Perm current rating in duct 30°C: 72 A
- Perm current rating in air 30°C: 89 A
5X8AWG
Nexans ref. 10018209
- Conductor cross-section: 8.37 mm²
- Conductor cross-section (AWG/KCMIL): 8
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 89 A
- Permissible current rating buried/duct 20°C: 63 A
- Perm current rating in duct 30°C: 54 A
- Perm current rating in air 30°C: 67 A
5X10AWG
Nexans ref. 10022090
- Conductor cross-section: 5.26 mm²
- Conductor cross-section (AWG/KCMIL): 10
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 69 A
- Permissible current rating buried/duct 20°C: 48 A
- Perm current rating in duct 30°C: 38 A
- Perm current rating in air 30°C: 50 A
5X2AWG
Nexans ref. 10048296
- Conductor cross-section: 33.6 mm²
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 189 A
- Permissible current rating buried/duct 20°C: 132 A
- Perm current rating in duct 30°C: 125 A
- Perm current rating in air 30°C: 154 A
5X12AWG
Nexans ref. 10022091
- Conductor cross-section: 3.31 mm²
- Conductor cross-section (AWG/KCMIL): 12
- Conductor cross-section: - kcmil
- Permissible current rating buried 20°C: 39 A
- Permissible current rating buried/duct 20°C: 38 A
- Perm current rating in duct 30°C: 31 A
- Perm current rating in air 30°C: 38 A
1x250kcmil
Nexans ref. 10003172
- Packaging: Cut to length (300m)
- Conductor cross-section: 127 mm²
- Conductor cross-section (AWG/KCMIL): 250
- Conductor cross-section: 250 kcmil
- Permissible current rating buried 20°C: 396 A
- Permissible current rating buried/duct 20°C: 270 A
- Perm current rating in duct 30°C: 322 A
- Perm current rating in air 30°C: 415 A
3X250kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section: 127 mm²
- Conductor cross-section (AWG/KCMIL): 250
- Conductor cross-section: 250 kcmil
- Permissible current rating buried 20°C: 396 A
- Permissible current rating buried/duct 20°C: 270 A
- Perm current rating in duct 30°C: 277 A
- Perm current rating in air 30°C: 358 A
4X250kcmil
Nexans ref. 10049189
- Conductor cross-section: 127 mm²
- Conductor cross-section (AWG/KCMIL): 250
- Conductor cross-section: 250 kcmil
- Permissible current rating buried 20°C: 396 A
- Permissible current rating buried/duct 20°C: 270 A
- Perm current rating in duct 30°C: 277 A
- Perm current rating in air 30°C: 358 A
1x350kcmil
Nexans ref. 10003175
- Packaging: Cut to length (300m)
- Conductor cross-section: 177 mm²
- Conductor cross-section (AWG/KCMIL): 350
- Conductor cross-section: 350 kcmil
- Permissible current rating buried 20°C: 474 A
- Permissible current rating buried/duct 20°C: 325 A
- Perm current rating in duct 30°C: 374 A
- Perm current rating in air 30°C: 518 A
3X350kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section: 177 mm²
- Conductor cross-section (AWG/KCMIL): 350
- Conductor cross-section: 350 kcmil
- Permissible current rating buried 20°C: 474 A
- Permissible current rating buried/duct 20°C: 325 A
- Perm current rating in duct 30°C: 331 A
- Perm current rating in air 30°C: 444 A
4X350kcmil
Nexans ref. 10048003
- Conductor cross-section: 177.3 mm²
- Conductor cross-section (AWG/KCMIL): 350
- Conductor cross-section: 350 kcmil
- Permissible current rating buried 20°C: 474 A
- Permissible current rating buried/duct 20°C: 325 A
- Perm current rating in duct 30°C: 331 A
- Perm current rating in air 30°C: 444 A
1x500kcmil
Nexans ref. 10003176
- Packaging: Cut to length (300m)
- Conductor cross-section: 253 mm²
- Conductor cross-section (AWG/KCMIL): 500
- Conductor cross-section: 500 kcmil
- Permissible current rating buried 20°C: 576 A
- Permissible current rating buried/duct 20°C: 393 A
- Perm current rating in duct 30°C: 464 A
- Perm current rating in air 30°C: 657 A
3X500kcmil
Nexans ref.
- Packaging: Cut to length (300m)
- Conductor cross-section: 253 mm²
- Conductor cross-section (AWG/KCMIL): 500
- Conductor cross-section: 500 kcmil
- Permissible current rating buried 20°C: 576 A
- Permissible current rating buried/duct 20°C: 393 A
- Perm current rating in duct 30°C: 410 A
- Perm current rating in air 30°C: 557 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2
Applications
Flexible power and control cable for fixed installations. Recommended in loops demanding extra-flexible cables. To be used especially in industrial buildings and substations. It can be installed in free air, in ducts or directly buried. It can be installed submerged in water.
In small sizes, it is used as control cable for the inner part in cabinets.
Construction: Singlecore or multicore copper conductor from 3 to 5 cores.
Conductor: Class 5 flexible copper conductor according to IEC 60228.
Insulation: Crosslinked Polyethylene (XLPE) with excellent electrical properties, good resistance to ozone and chemical agents. Cores identification by colors.
Oversheath: Black color Polyvinyl Chloride (PVC), flame retardant, resistant to weather and UV radiation. available in other colors upon request.
Marking:
Nexans MULTI-FLEX SERIE 2 RV-K "size" 0.6/1 kV (Um=1,2kV) 90°C INGCER E-021-14-4022 "Manuf. order" "Date" CHILE "sequential footage"
Design Alternatives
MULTIFLEX-RAT: Resistant to rodent attack.
MULTIFLEX-BLIND: Shielded with copper tape.
MULTIFLEX-BLIND-TZ: Shielded with a tinned copper braid.
Other rated voltages upon request: 1,8/3 kV.
Fire Safety alternative:
FREETOX-FLEX SERIE 3 RZ1-K
INSTALATION CONDITIONS FOR CURRENT CARRYING CAPACITIES
Current carrying capacities based on table N°4.4 according to RIC N°4, They are applied for installations where ducts and cables are not directly exposed to solar radiation.
(3) direct current buried at 20°C: Sheathed, single conductor or multi conductor cables (Three conductors with load) installed directly buried. Installation Method D2 according to RIC N°4.
(4) current in buried duct at 20°C: Single conductor or multi conductor cables (three conductors with load) installed in buried ducts. Installation Method D1 according to RIC N°4.
(5) duct current at 30°C: Up to three single conductors or multi conductor cables (three conductors with load) installed in ducts or trays attached to walls. Installation Method B1 and B2 according to RIC N°4.
(6) air current at 30°C: Multiconductor cables (Three conductors with load) installed freely in the air, in conductor ladders or in conductor baskets or in perforated trays. Installation Method E according to RIC N°4. Single conductor cables: Three conductors with load, in contact and in a flat arrangement, installed freely in the air, on conductor ladders or in conductor baskets or in perforated trays. Installation Method F according to RIC N°4.
For buried installations, a depth of 0,7 meters and a thermal resistivity of the soil of 1 K*m/W.
Current capacity correction factors must be considered according to the specific installation conditions.
INSTALATION CONDITIONS FOR CURRENT CARRYING CAPACITIES
NOTES
Values not defined as "maximum", "max.", "minimum" or "min." are not normative requirements in the standard and they are indicative only.
CERTIFICATE SEC RV-K
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania